Document Type : Original Article
Authors
1 Dental Materials Research Center, Associate professor, Department of Orthodontics, Faculty of Dentistry, Mashhad, Iran
2 Assistant Professor, Orthodontic Department, School of Dentistry, Islamic Azad University of Medical Sciences, Tehran, Iran
3 Assistant Professor, Department of Oral and Maxillofacial Radiology, School of Dentistry, Zahedan University of Medical Sciences, Zahedan, Iran
4 Department of Materials Science and Engineering, Engineering Faculty, Shiraz University, Shiraz, Iran
Abstract
Keywords
Main Subjects
Introduction
As we know, nickel-titanium and stainless steel wires are widely used in orthodontic practice. Since most people do not follow a satisfactory oral hygiene regime during treatment, orthodontic treatment may have detrimental effects on tooth structures or periodontium. For this reason, using different mouthwashes to control dental caries or periodontal disease is recommended to patients. However, chemical agents may be potentially damaging to metal components of orthodontic appliances (1, 2).
Chlorhexidine is an agent with antibacterial properties, which is widely used in clinical dentistry, and has a special affinity for oral structures. The effect of Chlorhexidine in inhibiting plaque formation and reducing bacteria in the oral cavity, including streptococci, is well established in the literature (3).
Persica is another mouthwash that is widely used in the Middle East and proven to have antibacterial effects on cariogenic bacteria (4); the effects of this mouthwash have been investigated in the UK, USA and the Middle East (5-7).
Hydrogen peroxide (H202) is an effective bactericidal agent that catalyzes salivary peroxidase to form products with antibacterial properties (8, 9). It has been proven that even low levels of H202, either directly or by adding H202-generating systems, would be the most effective approach for inhibiting acid production and growth of streptococci(1).
Although orthodontic alloys show resistance against corrosion in various solutions as a result of the thin passive oxide film on their surface, this protective layer is susceptible to some chemical disruption (10-12).
The corrosion of orthodontic appliances in the oral environment has concerned clinicians about two principle issues: absorption of corrosion products in the body with local or systemic effects and the effect of corrosion on metal parts with regard to friction. Corrosion can adversely affect tooth movement because of the induced pitting and porosity on the surface of metal parts, which consequently increase the friction between the wire and the bracket slot. The friction behavior between an orthodontic wire and brackets can affect surface topography and vice versa (13). According to our knowledge, there has not been any studies on the effect of different mouthwashes (Except fluoride mouthwashes and Chlorhexidine) on surface topography of orthodontic archwires, therefore the purpose of the present study was to evaluate the effects of the three mouthwashes on surface characteristics of nickel–titanium NiTi and stainless steel (SS) wires.
Materials and Methods
Figure 1. Pre-processing applied on a sample image :(A) The original image.
Figure 1(B). Detected noise particles
Figure 1(C). Removing noise particles from the image
Figure 2. Nominate holes part of the sample image: (A) an improved image.
Figure2(B). Internal surface of hole from conversion of thehat – bottom
Figure2(C). External hole borders from conversion of the hat-top
Figure 2(D). Holes have been nominated
Figure 3. Identified holes for a sample image: (A) an improved image.
Figure 3(B). Identified holes Tables
Results
The effects of Chlorhexidine, hydrogen peroxide and Persica on topography properties of NiTi and SS wires were compared with 2 control groups. The mean values of corrosion percentage and hole count of NiTi and SS wires in different mouthwashes and artificial saliva are shown in Table 1.
Comparison pairs of corrosion percentage of NiTi wires (Table 2) showed that There was significant difference between Persica and as-received (P=0.049) and Chlorhexidine and as-received (p=0.20) arch wires.
Aspect of hole numbers in NiTi wires, there were no significant difference between none of the groups (P-value>0.05) but it is interesting that in this wire is highest corrosive appearance was in as-received group.
Comparison of the number of cavities and corrosion percentage of SS wires in pairs are shown in Table 3. In this type wire, Chlorhexidine was dominant media for corrosive effect but non-significant (P-value>0.05)
Table1. The mean of corrosion percentage in NiTi and SS wires
Mouthwash |
corrosion percentage Mean±SD |
Number of holes |
||
NiTi |
SS |
NiTi |
SS |
|
Persica |
6.18±0.91 |
3.07±0.978 |
6.6±0.848 |
4.4±0.282 |
Chlorhexidine |
5.40±0.75 |
5.30±4.330 |
9.7±3.252 |
5.4±1.97 |
Peroxide |
6.35±1.076 |
3.33±1.101 |
6.6±1.97 |
4.8±3.11 |
Artificial saliva |
4.48±0.418 |
2.03±0.908 |
6.6±0.848 |
4.2±0.565 |
As-recieved |
9.22±0.308 |
4.100±0.250 |
11.9±2.121 |
4.6±1.97 |
SD: Standard Deviation
Table 2. A comparison between different mouthwashes and control groups in NiTi wires
MOUTHWA(I) |
MOUTHWA(J) |
corrosion percentage |
Number of holes |
||
|
|
Mean Difference(I-J) |
Sig. (p-value) |
Mean Difference(I-J) |
Sig. (p-value) |
Persica |
Chlorhexidine |
0.78 |
0.82 |
-3.100 |
0.586 |
peroxide |
-0.16 |
0.99 |
0.0000 |
1.000 |
|
artificial saliva |
1.70 |
0.29 |
0.0000 |
1.000 |
|
as-received
|
-3.04 |
0.049* |
-5.3000 |
0.201 |
|
Chlorhexidine |
Persica |
-0.78 |
0.82 |
3.1000 |
0.586 |
peroxide |
-0.95 |
0.72 |
3.10 |
0.58 |
|
artificial saliva |
0.91 |
0.74 |
3.10 |
0.58 |
|
as-received
|
-3.82 |
0.020* |
-2.20 |
0.80 |
|
Peroxide |
Persica |
0.16 |
0.99 |
0.00 |
1.00 |
Chlorhexidine |
0.95 |
0.72 |
-3.10 |
0.58 |
|
artificial saliva |
1.87 |
0.23 |
0.00 |
1.00 |
|
as-received
|
-2.87 |
0.06 |
-5.30 |
0.20 |
|
As-received |
Persica |
3.04 |
0.049* |
5.30 |
2.20 |
Chlorhexidine |
3.82 |
0.020* |
5.30 |
5.30 |
|
peroxide |
2.87 |
0.060 |
0.201 |
0.80 |
|
artificial saliva
|
4.74 |
0.008* |
0201 |
0.20 |
|
artificial saliva |
Persica |
-1.70 |
0.29 |
0.00 |
1.0 |
Chlorhexidine |
-0.91 |
0.74 |
-3.10 |
0.58 |
|
peroxide |
-1.87 |
0.23 |
0.00 |
1.00 |
|
as-received |
-4.74 |
0.008* |
-5.30 |
0.20 |
Table3. A comparison between different mouthwashes and control groups in SS wires
MOUTHWA(I) |
MOUTHWA(J) |
corrosion percentage |
Number of holes |
||
|
|
Mean Difference(I-J) |
sig |
Mean Difference(I-J) |
sig |
Persica |
Chlorhexidine |
-2.22 |
.817 |
-1.00 |
0.980 |
peroxide |
-0.25 |
1.00 |
-0.400 |
0.999 |
|
artificial saliva |
1.04 |
0.98 |
0.200 |
1.000 |
|
as-received
|
-1.02 |
0.98 |
-0.200 |
1.000 |
|
Chlorhexidine |
Persica |
2.22 |
0.81 |
1.00 |
0.980 |
peroxide |
1.97 |
0.86 |
0.60 |
0.997 |
|
artificial saliva |
3.26 |
0.57 |
1.20 |
0.963 |
|
as-received
|
1.20 |
0.97 |
0.800 |
1.000 |
|
peroxide |
Persica |
.25 |
1.0 |
0.40 |
0.999 |
Chlorhexidine |
-1.97 |
0.86 |
-0.60 |
0.997 |
|
artificial saliva |
1.29 |
0.96 |
0.60 |
0.997 |
|
as-received
|
-0.76 |
0.99 |
0.20 |
1.000 |
|
as-received
|
Persica |
1.02 |
0.98 |
0.20 |
1.000 |
Chlorhexidine |
-1.20 |
0.97 |
-0.80 |
0.991 |
|
peroxide |
0.76 |
0.99 |
-0.200 |
1.000 |
|
artificial saliva
|
2.06 |
0.85 |
0.40 |
0.999 |
|
Artificial saliva |
Persica |
-1.04 |
0.98 |
-0.20 |
1.000 |
Chlorhexidine |
-3.26 |
0.57 |
-1.20 |
0.963 |
|
peroxide |
-1.29 |
0.96 |
-0.60 |
0.997 |
|
as-received |
-2.06 |
0.85 |
-0.40 |
0.999 |
Discussion
Orthodontic treatment involves the application of dental arch wires and attachments for tooth movement. Since the appliances are present in the mouth and exposed to altered biological conditions, orthodontic patients are more prone to gingivitis and enamel decalcification; Therefore, to reduce these potential risks, mouthwash application along with brushing is important. On the other hand, we must be aware of the effects of the mouthwash on the various components of the orthodontic appliances.
The alloy used in orthodontic wires (nickel-titanium and stainless steel) have a high resistance to corrosion that relates to the protective layer on its surface. Protective layer of NiTi and stainless steel wires are titanium oxide and chromium oxide, respectively. Yet this protective layer is susceptible to both mechanical and chemical disruption (16).
Overall, according to the obtained results of this study, the rate of corrosion was higher in NiTi wires than SS wires. Moreover, NiTi wires, soaked in Chlorhexidine or Peroxide or Persica, had no significant difference in corrosive behavior compared to the artificial saliva group. Corrosion percentage in our results were consistent with the results of Bundy K (17) and Rondelli G (18) that showed Orthodontic wires in various solutions such as Ringer, artificial saliva and NaCl had a high resistance to corrosion (19). In these solutions, the corrosion resistance of titanium alloys is higher than that of stainless steels alloys from the viewpoint of film breakdown (19).
In NiTi wires, high corrosion percentage was seen in peroxide mouthwash compared to as received group. The destruction of the protective layer of NiTi wire due to low PH (3.6) can lead to increased penetration of hydrogen peroxide. Also, hydrogen peroxide can lead to release of high amounts of OH radicals in metal surface, which can play an important role in the destruction of the surface layers of NiTi wire (20). Previous studieshave stated that in an acidic environment, the corrosion predisposition of certain metals especially titanium, is increased (16, 21).
In this study, it was observed that as-received wires had highest surface defects. Surface defects and roughness produced during the manufacturing processes has been reported in some investigation(s) (22).
These are prominences created during wire manufacturing that seems to be worn wire immersion in mouthwashes.
The degree of stainless steel corrosion in different mouthwashes such as EDTA, chlorhexidine (0.2%), and NaCl (5.25%) was assessed by the Dartar Oztan et al. and its result showed that there was corrosion in stainless steel files, especially pitting corrosion, in chlorhexidine solution (23). Hosseinzadeh Nik et al showed chlorhexidine-containing mouth rinses may be prescribed as non-destructive prophylactic agents (24). The surface of ORJ brackets showed significant changes under a light microscope indicating the staining of these brackets in acidic artificial saliva. This corrosion results in the release of corrosion products into the oral cavity. [DHB1] (25)In this regard, conflicting results may be due to differences in the type of material used in the researches and the application duration of mouthwashes. According to our study, while with no significance, the highest amount of corrosion was observed in stainless steel wires immersed in Chlorhexidine solution and peroxide and Chlorhexidine have more detrimental effects on NiTi and Stainless steel wires respectively. Intergranular corrosion is also observed on the surface of these brackets that can lead to staining of SS brackets followed by their weakening and eventual fracture.(26)
Conclusion
Based on our results, the following points expressed:
1. Alterations in surface of NiTi wires were significantly more than SS wires.
2. Although not significant, 0.12% Chlorhexidine and Peroxide showed higher pitting view on SS and NiTi wires respectively, compared to other mouthwashes.
3. The mouthwashes should be prescribed according to the orthodontic materials used to reduce side effects of some mouthwashes.
[DHB1]The phrase “affects the service of theses….) does not make sense. Please revise the sentence.
References
Soodeh Tahmasbi ,Mohammad Ghorbani , Mahdis Masudrad. Ion Release from Various Orthodontic Brackets and Wiresina Fluoride-containing Mouthwash.J Dent Res Dent Clin Dent Prospect 2015: 9(3):159-165