Document Type : Original Article
Authors
1 Dr. Ahmed Ayub Patel MDS, Department of Prosthodontics M. A. Rangoonwala College of Dental Sciences and Research Centre Pune +919518788305
2 Dr. Ramandeep Dugal MDS, HOD and Professor Department of Prosthodontics M. A. Rangoonwala College of Dental SCiences and Research Centre Pune
3 Diploma Dental Materials Rural Dental College, Loni, India
4 Dr. Aamir Zahid Godil MDS, Senior Lecturer Department of Prosthodontics M. A. Rangoonwala College of Dental Sciences and Research Centre Pune +918160666576 +919049210549
5 Department of Prosthodontics, Post-graduate Student, M. A. Rangoonwala of Dental Sciences and Research Centre, Pune, Maharashtra, India
6 Dr. Ajinkya Sanjiv Kirad MDS, Department of Prosthodontics M. A. Rangoonwala College of Dental Sciences and Research Centre Pune
Abstract
Keywords
Main Subjects
Introduction
An interim or provisional restoration functions as a temporary prosthesis for the prepared tooth before final one is delivered (1). Success of provisional restoration depends upon good marginal adaptation as it promotes gingival health during the period between tooth preparation and placement of final restoration. It also prevents from any thermal, bacterial and chemical insults to the pulp. A poorly adapted provisional restoration induces plaque accumulation leading to periodontal disease ranging from gingival inflammation to periodontal support breakdown (2-11).Proper fit of provisional restoration and low solubility of cement are two factors that would reduce any discomfort for the patient during the interim period before permanent restoration delivery (8). The longer provisional restoration is on the tooth, the higher chance that its fit and contour will affect the health of gingival tissue. Various clinical situations may require a provisional restoration for an extended period such as surgical crown lengthening procedures, full mouth prosthetic rehabilitations and certain cases of immediate implant placement. Different interim restoration materials are used that can be divided into four groups according to their composition: polymethyl methacrylate (PMMA), polyethyl or butyl methacrylate, micro filled bisphenol A-glycidyl dimethacrylate (Bis-GMA) composite resin and urethane dimethacrylate (light polymerizing resins). The primary monomer determines many of material characteristics such as polymerization shrinkage, strength and exothermic heat of reaction (10). Bis-acryl composite resin-based materials are commercially popular because of their handling properties, ease of use and superior mechanical properties, including hardness, flexural strength, and modulus of elasticity (2, 12-15).However, polymerization shrinkage, exothermic setting reaction and irritation associated with monomer are amongst the material’s disadvantagesand relatively lower levels of finish and fine marginal adaptation have been reported (4,16-18). Moreover, working and resultant biophysical properties can be influenced by monomer to powder ratio. Recently, visible light cured resins have been introduced based on urethane dimethacrylate. These relatively expensive resins have good mechanical properties and because of light cure polymerization, the operator has more control over material’s working time. Polymers made with low molecular weight urethane dimethacrylates have similar or slightly less water sorption than polymers prepared from bis-GMA (19, 20).Lately, a newer dual-cure material has been introduced as a provisional restoration material, i.e. rubberized urethane which provides a better marginal adaptation and ease of application compared to self-cure acrylic temporization materials. Further, it claims to have better strength and polishing characteristics that might serve as a promising evolution to the existing interim materials. Very limited literature exists on performance of dual cure rubberized urethane based temporary materials. Therefore, this study was undertaken to evaluate and compare the marginal accuracy of this material in comparison to already existing commercially popular interim restorative materials over two intervals: one hour after fabrication and after one week.
Materials and Methods
An Ivorine® mandibular right first molar typodont tooth (Columbia Dentoform Corp, New York) was prepared for a full coverage crown with a 1- mm chamfer (SO-21, Mani, Japan) finish line and a taper of approximately 5 degrees. An impression of prepared crown extending up to the apex of the typodont was made using polyvinylsiloxane (PVS) (Affinis, Coltene, Switzerland). Type II inlay wax was poured into impression of the prepared crown. In laboratory, a metal die using base metal was fabricated from the wax pattern using lost wax technique. The metal die was called as master die. Die was finished and polished and four vertical reference points were marked on the buccal, lingual, mesial and distal sides respectively.
The metal die was lubricated with petroleum jelly and a wax pattern was made on the metal die with Type II inlay wax. Wax pattern was made to simulate anatomy of mandibular first molar. It served two purposes; 1) To make matrix for fabrication of crowns using interim material 2) To mark the proper orientation of crown matrix with master die. A putty matrix was essential to hold the provisional restorative material over the prepared tooth. PVS putty impression of the die was made along with crown analogue. For this, an equal amount of base and catalyst material of the putty impression material was mixed as per the manufacturer’s directions with respect to proportioning and mixing and was placed over the die. The polymerized impression served as the matrix for making provisional restorations.
A total of sixty samples, twenty from each group were fabricated on prepared customized metal die following the manufacturer’s instructions. Three test groups were Group A - ProtempTM 4 (3M ESPE AG Dental Products, Germany), a bis-acrylic based self-cure temporary material; Group B - Revotek LCTM (GC Dental Products Corp., Japan), a urethane dimethacrylate based light cure temporary material and Group C - Tuff-Temp™ Plus (Pulpdent Corporation, U.S.A), a rubberized-urethane based dual cure temporary material. (Figure 1)
Figure 1 – Preparation of Samples
Group A; (ProtempTM 4) was mixed with the help of dispensing gun (10:1) and was loaded onto the putty matrix and adapted on the lubricated metal die. The interim restorations were removed and reseated once during the elastic phase of polymerization. Before complete polymerization, excess flash was trimmed from the margins of interim restorations with scissors. After polymerization was completed, the crowns were trimmed and finished as per the manufacturer’s guidelines.
Group B; (Revotek LCTM) interim restorations were made following the same protocol. Initial light curing (LED Woodpecker) was done for 10 seconds, to prevent possible deformation during removal. The interim restoration was removed and reseated once during the elastic phase of polymerization. Each of the buccal, proximal, occlusal and lingual surfaces were light cured for 20 seconds. After final curing was done, finishing and polishing was done by similar operator using a micromotor hand piece.
Group C; (Tuff-Temp™ Plus) interim restorations were also made following the same protocol. After two minutes from its initial stage of polymerization, crown was removed from the matrix and excess flash was trimmed. Before the final light curing, removal of oxygen inhibited layer on the surface was done by using alcohol. Final light curing was done at each of the buccal, proximal, occlusal and lingual surfaces for 20 seconds.
The test samples that were stored in artificial saliva were taken for testing under a stereomicroscope. A total number of sixty samples prepared from three groups of interim materials were evaluated for marginal discrepancy, one hour after fabrication. The marginal gaps were measured at four vertical reference points on buccal, lingual, mesial and distal sides respectively. Measurements extended from edge of the chamfer finish line vertically above the mid-point of die’s score point to the inferior edge of the provisional crown using a stereomicroscope (Mode: XTL 3400E – Magnification:10X, Wuzhou New Found Instrument Co. Ltd., China) under 10x magnification. An image analyzing system (Chroma Systems PVT. Ltd, India; Model – MVIG 2005) was used to obtain numerical values in microns (µm). The readings thus obtained, were noted. The samples were stored in artificial saliva for a week and same tests were performed afterwards. (Figure2-7) Statistical results were drawn using one way ANOVA and Tukey’s Post-hoc test to understand the multiple individual comparison among different interim restorative materials to assess marginal discrepancies at one hour and one week intervals for the three test materials.
Figure 2 – Marginal Discrepancy Of ‘Group A’ After 1 Hour |
Figure 3 – Marginal Discrepancy Of ‘Group B’ After 1 Hour |
Figure 4 – Marginal Discrepancy Of ‘Group C’ After 1 Hour |
Figure 5 – Marginal Discrepancy Of ‘Group A’ After 1 Week |
Figure 6 – Marginal Discrepancy Of ‘Group B’ After 1 Week |
Figure 7 – Marginal Discrepancy Of ‘Group C’ After 1 Week |
Results
One-way ANOVA test was used to determine which groups differ from each other, P-value < 0.05 was considered significant. It was found that there was statistical significant difference between the means of three interim restorative materials after one hour (f= 447.41, P<0.05). Among which, Tuff-Temp™ Plus showed the least marginal discrepancy, while Revotek LCTM had the highest discrepancy. Also, there was a statistically significant difference between three means of marginal discrepancy of same materials after one week (f=580.612, P<0.05). Among which, Tuff-Temp™ Plus had the least marginal discrepancy, while Revotek LCTM had the highest discrepancy. Comparison of mean marginal discrepancy after one hour and one week interval by one-way ANOVA is depicted in Table I. Also, theinter-group comparison is described in Table II and graphical summary of results is shown in Figure 8.
Table I: Comparison of Mean Marginal Discrepancy after One Hour and One Week Interval by One-way ANOVA Test
Groups (N=20) |
Mean (µm) |
Standard Deviation |
F Value |
P-Value |
After 1 Hour |
||||
Group A (Protemp™ 4) |
201.3 |
7.67 |
447.412 |
<0.05, Significant |
Group B (Revotek LCTM) |
232.52 |
0.48 |
||
Group C (Tuff Temp™ Plus) |
192.3 |
0.75 |
||
After 1 Week |
||||
Group A (Protemp™ 4) |
248.86 |
5.83 |
580.612 |
<0.05, Significant |
Group B (Revotek LCTM) |
293.68 |
3.75 |
||
Group C (Tuff Temp™ Plus) |
242.69 |
5.64 |
Table II: Inter-Group Comparison using Tukey’s Post -Hoc Test
Groups (N=20) |
Mean Difference (µm) |
P -Value |
|
|
|||
Group A Vs Group B |
After 1 Hour 31.22 |
<0.05, Significant |
|
Group B Vs Group C |
40.17 |
<0.05, Significant |
|
Group A Vs Group C |
8.95 |
<0.05, Significant |
|
Group A Vs Group B |
After 1 Week 44.81 |
<0.05, Significant |
|
Group B Vs Group C |
50.99 |
<0.05, Significant |
|
Group A Vs Group C |
6.17 |
<0.05, Significant |
Figure 8 – Graphical Representation of Results
Discussion
Interim treatment promotes numerous adjunct benefits to definitive prosthodontic treatment and each of these benefits has a role to play in success of a fixed prosthesis (21). Traditionally, thermoplastic acrylic [PMMA and MMA] materials have been used as the provisional material of choice and have, to a certain degree, met many of the mechanical and physical requirements. However, they have their own shortcomings. The newer composite temporization materials have become an increasingly popular choice due to their improved mechanical properties, decreased exothermic release and ease of handling.With the advent of high density cross linked polymers, nanocomposites and visible light cure resins; newer temporary materials have become commercially available claiming to have superior properties. These materials usually incorporate filler such as microfine silica to improve physical properties (13, 22, 23). The choice of materials on which this study was conducted was determined by the fact that sufficient literature reports have advocated bis-acryl composites and light cure UDMA as promising interim materials; however, there is very limited data on the performance of dual cure temporary materials. To assess the nature of these dual-cure resins, Tuff TempTM Plus was chosen as a test material. A variety of techniques exist for fabricating provisional materials. While several studies have used both direct and indirect techniques and advantages and disadvantages cited for each one, it does not seem to have any indication in literature as to which technique is most accurate (24). In this study, provisional restorations were fabricated by indirect method and in particular by using the "on-off" technique described by Moulding et al, for which interim crowns are removed once from prepared tooth on initial polymerization and then reseated (25,26). Review suggests that aging of provisional restoration, temperature fluctuations and the moisture also accelerate discrepancy at margins. This is due to crack propagation in weaker areas as a result of contraction and expansion at the margins. Therefore, aging of samples in artificial saliva was performed in this study (27). The current study used direct view technique using a stereomicroscope. Nawafleh et al. (28) advocated this technique in their literature review that elaborates on accuracy and reliability of methods to measure marginal adaptation of crowns and FDPs. The statistical analysis of this study showed that there was a significant difference between mean values of three interim test materials, among which Tuff TempTM Plus (192.3± 0.75µm) which is a dual cure rubberized UDMA polymer showed least marginal discrepancy followed by ProtempTM 4 (201.3±7.67µm), a bis-acryl, self-cure polymer. Revotek LCTM (232.52± 0.48µm) which is a light cure UDMA polymer, shows maximum marginal discrepancy after one hour. Stereomicroscopic values obtained at an interval of one week, in the current study also showed similar results as obtained after one hour. It was noted that Tuff TempTM Plus (242.69 ± 5.64µm) had minimum marginal discrepancy and Revotek LCTM (293.68 ± 3.75µm) had highest marginal discrepancy. The values of marginal discrepancy are higher than clinical acceptable range of 100-150μm for a provisional crown (29). These could possibly be an outcome of polymerization shrinkage and differences in testing conditions. Tjan et al. (26) checked marginal fidelity of six provisional materials and concluded that crown fabricated with EMA and bis-acrylic composite recorded the least marginal discrepancy followed by bis-GMA and MMA and then by UDMA and highest by MMA. Another study by Verma R et al. (30) recorded least marginal discrepancy with provisional restorations made from bis-GMA. From the study conducted by Koumijan and Holmes, it was concluded that light cure polymers have a lesser marginal discrepancy as compared to bis-acryl self-cure polymers immediately, in air and in water media; which is similar to results of our study (31). Results of our study differed from a study conducted by Gudapati et al. (32) which suggests that light cure polymers have a higher marginal accuracy as compared to auto-polymerising bis-acryl composite because of difference in their thermal expansion coefficient which alters polymerization shrinkage. The disparities in these results may be attributed to variations in study configurations and difference in commercial brands of test materials (33).The marginal superiority of light cure provisional materials has been reported byNivedita S and Prithviraj DR using scanning electron microscopy.(34) The results of this study show that for light cure materials (Revotek LCTM), the initial marginal discrepancy was lesser as compared to one week. It can be hypothesized that the initial marginal error of light cured materials may be associated with controlled setting reaction and prolonged working time available before beginning the light curing. Furthermore, better primary outcomes with light cure materials may be attributed to its physicochemical properties and filler content. These factors contribute to less shrinkage and better primary outcomes. On the other hand, since self-cure materials (ProtempTM 4) undergo rapid auto-polymerisation, they provide a limited working time (35, 36). Degree of conversion (DC) also affects the polymerization shrinkage over and above the chemical composition of materials. DC in a polymer structure is the ratio of single carbon-carbon bonds to double carbon-carbon bonds among monomers (2, 37-39). In dual cure rubberized UDMA (Tuff-TempTM Plus), the marginal accuracy was superior as compared to the other two test groups. This could be due to the rubber filler in the matrix which serves as cross linking agent that delays the degree of conversion and provides adequate time until light curing is complete. This minimizes polymerization shrinkage and provides a favorable marginal accuracy. Since, Bis-GMA materials have high molecular weight, there is only a partial conversion of double bonds of bis-acrylate to single bonds. This is possibly associated with loss of mobility and reduced reactivity of free polymer radicals in dense polymeric network after setting (37, 39). These materials still show acceptable mechanical properties, despite their low degree of conversion, since these are multifunctional monomers with more than two reactive double bonds per molecule. Hence, resulting in a higher density of cross-links in a decreased degree of conversion (37). Similarly, monomethacrylates show higher polymerization shrinkage compared to composites due to lower molecular weight of monomers involved (6,36,40).Moreover, the differences in fabrication procedures of these samples might account for the variation in results. Mechanical properties are attributed to proper initiation or mature termination of polymerization process.(36) The control during the preparation of photo-polymerized materials might be greater than self-cured ones due to void entrapment , residue of poorly blended materials and deviations from the optimum proportions required for consistent mix (6,38). Furthermore, additional contraction may occur due to the exothermic polymerization reaction on cooling of self-curable material, unlike. light-curable composites (36). Although in the current study, dual cure materials have shown superior marginal accuracy compared to self-cure and light cure materials; these findings cannot be generalized for all commercially available temporary materials. More research including a variety of test materials with special emphasis on their chemical reaction and polymerization processes can provide a better insight on clinical performance of these materials.
Conclusions:
The comparison of marginal accuracy of three different interim restorative materials showed statistically significant differences. It was concluded that dual cure rubberised UDMA polymer (Tuff-Temp™ Plus) had the highest marginal accuracy followed by bis-acrylic based material (ProtempTM 4) and UDMA based light cure temporary material (Revotek LCTM) at one hour and one week intervals.
Conflicts of interest:
There are no conflicts of interest in this study.
Acknowledgement:
No acknowledgements